Safety instructions symbols
Safety precautions
Safety instructions
- Before using the product, please read the user manual thoroughly and follow the safety rules.
- Keep this manual in a safe place for future reference.
- Do not modify, disassemble, or assemble the product arbitrarily.
- Observe the conditions of use specified on product's label or instruction.
- Operate, install, and disassemble product after confirming the safety of the surrounding conditions.
- For use in unspecified conditions or environments, we recommend that you thoroughly review safety measures and consult with us.
Qualifications of professional personnel
- We recommend handling by a person with sufficient knowledge and experience about the product.
- The person who determines the design or specifications of the system should determine whether the product is suitable for use.
Warranty and disclaimers
- For standard products, the warranty period is applied within 1 year from the date of use or within 18 months after delivery, whichever comes first.
- During the warranty period, if a failure or damage is clearly attributable to our company, we will provide a replacement/necessary replacement part, and we will not bear any additional loss. Warranty here means the warranty for our products, and any other damage caused by the failure of the product is excluded from the scope of the warranty.
Specifications
- Fluid : filtered compressed air
- Ambient and fluid temp. : 0~60℃ (with no freezing)
- Drain type : for both auto and manual drain
- Drain port size : Ø6 one touch fitting
- Max. Flow rate
- ~~KWS200-02 : 200 Nℓ/min
- ~~KWS300-03 : 300 Nℓ/min
- ~~KWS600-04 : 600 Nℓ/min
- ~~KWS800-10 : 1,500 Nℓ/min
- Max. Operating pressure
- ~~KWS200-02 / KWS300-03 / KWS600-04 : 1~10.2kgf/㎠ (0.1~1.0MPa)
- ~~KWS800-10 : 2~10.2kgf/㎠ (0.2~1.0MPa)
- Port size
- ~~KWS200-02 : Rc(PT)1/4”
- ~~KWS300-03 : Rc(PT)3/8”
- ~~KWS600-04 : Rc(PT)1/2”
- ~~KWS800-10 : Rc(PT)1”
Functions
<div class="cms-symbol-block">
<div class="image light-mode-images"><img src="https://cdn.prod.website-files.com/6577e4ddb18c5363e98a478a/65a78a466681fc260805d595_symbol__kws222.png" class="manual-symbol-img"><div class="cms-symbol-text"></div></div>
<div class="image dark-mode-images"><img src="https://cdn.prod.website-files.com/6577e4ddb18c5363e98a478a/65a786ba36944b47521c03be_symbol__kws_dark.png" class="manual-symbol-img"><div class="cms-symbol-text"></div></div>
</div>
Product configuration
<div class="image light-mode-images manual-full-img"><img src="https://cdn.prod.website-files.com/6577e4ddb18c5363e98a478a/65c18b8a657cd3b0d3d5176c_KWS__Str__en.png"></div>
<div class="image dark-mode-images manual-full-img"><img src="https://cdn.prod.website-files.com/6577e4ddb18c5363e98a478a/65c18b8a11c135c8ba8c1a32_KWS__Str_dark__en.png"></div>
Installation and disassembly
Precautions before installation
<div class="ico_danger">Installation and disassembly of a pressurized product may cause personal injury and/or property damage.</div>
<div class="ico_danger ico_2ndline">Before installation, be sure to release the pressure inside the product and piping.</div>
- Ensure free space around the product for maintenance and safe operation.
- Do not install in a location with high humidity or temperature. Doing so may cause performance degradation or malfunction.
- Avoid dropping and external impacts when transporting and installing the product.
- Connect the pneumatic pipe after completing the installation.
- When connecting only the pneumatic pipe, without a separate mounting device, consider installing a separate pipe support to prevent excessive moment load or vibration on the pipe side. Otherwise, a malfunction or damage may occur.
- Before installing the piping, flush or clean the piping sufficiently to remove any foreign substances. Even when fastening piping or fittings, make sure that chips from the piping screws or sealing material do not move into the machine. These may cause malfunction.
- In case a lubricator is used for the lubrication of an air cylinder, etc., install a deoiler in front of the lubricator.
- Be sure to install the deoiler “immediately before” the final equipment. If the piping after a deoiler is long, condensation may occur due to the temperature difference between the inside and outside of the pipe.
- To prevent the clogging of a drain valve, installing a common filter just in front of a deoiler is recommended.
Pneumatic piping
- Check the flow direction and place the product. Check the IN and OUT or arrows on the product body.
- Fasten the threaded part of the pipe or fitting to the pneumatic port.
- Hold the female thread side and apply the proper torque.
- Insufficient tightening torque may lead to loosening or an improper seal. Excessive tightening torque may cause damage to screws, etc. - After completely sealing the pneumatic port, connect the pneumatic tube.
Drain piping
- Install vertically with the drain outlet facing down. It cannot be used in a lateral or upward orientation.
- For auto drain discharge piping, the auto drain kits (AD201F, AD301N, AD401N) use a ∅6 outer diameter (∅4 inner diameter) tube, and the length must be within 5 meters.
Disassembly
<div class="ico_danger">Before disassembly, be sure to release the pressure inside the product and pipe.</div>
- Exhaust air from the entire system and product.
- Press and release the lock on the pipe or fitting, then pull out the hose line.
- Loosen the fitting on the connecting flange and turn it out.
Maintenance
Air source
- Please use clean air.
- If the compressed air contains chemicals, organic solvents, synthetic oil, or corrosive gas, it may cause damage to parts or malfunction.
- Air containing a large amount of moisture or foreign substances can cause malfunction, so install an air dryer or an after cooler on the inlet side of the product.
Maintenance and inspection
- Regularly inspect the bowl for contamination, cracks, damage, and other deterioration. Use a neutral detergent for cleaning. If the contamination is severe, replacement is recommended.
- In case of cracks, damage, or other deterioration, replace it.
Drain release
<div class="image light-mode-images manual-half-img"><img src="https://cdn.prod.website-files.com/6577e4ddb18c5363e98a478a/65a792e87e15e97d1cbda983_kws_drain.png"></div>
<div class="image dark-mode-images manual-half-img"><img src="https://cdn.prod.website-files.com/6577e4ddb18c5363e98a478a/65a792e81dc43ed74d8e2ede_kws_drain_dark.png"></div>
- Open and close the drain valve manually. Use of tools may cause damage.
- Release the drain before the level of the drain reaches the baffle.
- ~~Manual drain : turn the drain valve handle counterclockwise to drain.
- ~~Float-type auto drain : when the water level in the drain reaches the appropriate level, it is automatically discharged.
You can force a discharge by pushing the lower outlet.
Cleaning
- Clean the exterior of the product periodically with a soft cloth.
Allowable detergents : soapy water (maximum 60°C), neutral detergent (without aromatic compounds)
Failures and measures
In case corrosive gas is contained in compressed air
- Remove the cause of gas mixing, replace the damaged parts.
In case parts are damaged due to external impact
- Remove the cause of external impact, replace the damaged parts.
In case the drain valve outlet is clogged with solid foreign matter, etc.
- Replace the bowl assembly.
In case flow consumption at exit exceeds the product’s specifications
- Replace it with a product with greater flow.
For additional information, please visit our web site or contact us.